The construction and operation of all rovers must comply with the CIRC Rover Safety Requirements unless an exemption has been granted.
Exemptions may be granted on a case-by-case basis by submitting a request to [email protected], including the problematic requirement and proposed alternative.
Rovers will be subject to safety compliance inspections by organizers whenever the rover is operational. Teams must resolve any issues to the satisfaction of the inspecting organizer before continuing operation.
All rovers will be required to pass an initial safety compliance inspection at some point between registration and the start of their first competition task.
Sufficient evidence (such as schematics, datasheets, calculations) of safety compliance must be provided to competition organizers by the Safety Report Deadline:
- For the Winter 2024 Challenge, by January 15, 2024.
- For the Summer 2024 Challenge, by June 19, 2024
Teams are encouraged to submit partial or full documentation at any time before the deadline for feedback from the organizers.
Safety Guidelines
The purpose of this document is to define and enforce a minimum standard of rover design for all CIRC participants. This standard is intended to reduce the likelihood of rovers creating safety hazards or environmental damage. Rovers which do not comply with this document will be excluded from CIRC until all issues are resolved. Any questions or requests for exemptions should be directed to [email protected].
A basic example of a report from the 2019/2020 competition.
Definitions
- The word “should” indicates a suggestion which may become a requirement in future competitions.
- A Circuit is one or more electricity-consuming devices (and the connections between them) which draw current from a single power source through a common circuit protection element.
- Regulators consume and provide power, with their input and outputs counting as at least one circuit each.
- The Current Rating of a component is the manufacturer-published value indicating the maximum acceptable amperage consumed or provided by the device in normal continuous conditions. Transient, burst, or peak current limits are not current ratings.
- The Current Rating of circuit protection is the amperage above which it is designed to interrupt current flow.
- Circuit Protection is a fuse or electromechanical circuit breaker which reliably interrupts excessive current flows through a connected circuit. Software-based solutions are insufficient. Motor controllers, power regulators, or other devices with current limiting capabilities are not sufficient for use as Circuit Protection. Self-resetting fuses are also insufficient.
- A Kill Switch is a physical switch mounted on a rover which, when pressed down, causes the interruption of power to all rover systems until the switch is manually reset.
Requirements
- Rovers must not include any flammable, environmentally damaging, or otherwise hazardous liquids or gasses, except:
- Within a permanently sealed component such as a battery;
- Commercially-available lubricants as required by mechanical assemblies, where care is taken to avoid overuse and contamination.
- Each rover must be equipped with at least one kill switch.
- The pressable area of the kill switch must be at least 10 cm2 and red in color. Levers or toggle switches are not acceptable.
- No other button on the rover may be red.
- Kill switches must be mounted on the top of the rover, with the button oriented toward the sky in the rover’s normal driving orientation.
- A keep out region must be maintained around the kill switch with a radius of 15cm: No components taller than the base of the kill switch may intrude on the keep out region.
- Kill switches must not be obstructed by a cover or sleeve which extends above the pressable surface, and must be mounted such that it will not be obstructed by other components during rover operation.
- The circuit including the kill switch must include appropriate circuit protection, and the “break” or “disconnect” current rating of the kill switch must exceed the current rating of the circuit protection.
- The function of the kill switch must not depend on the integrity of any power source or computerized system. Indirect switching by relays or similar devices is permitted as long as these are driven by the kill switch, and reliably turn off when their control line is disconnected.
- The function of the kill switch must not depend on the integrity of any particular wiring connection; for example, physically tearing the kill switch off the rover should produce the same effect as pressing it.
- If multiple kill switches are installed on the rover, pressing any one should cut all power to to the rover.
- The function of the kill switch must not be disabled or bypassed by any means.
- Rovers should have a remote motion stop for disabling a run-away rover, such as a dead man’s switch on a lead, or a radio-frequency system that operates independently of the rover communications system.
- Each battery must include or be installed with a single circuit protection element which protects all circuits supplied by the battery, and the battery itself.
- The current rating of this protection must not exceed the lesser of:
- The current rating of the battery;
- 150% of the sum of the current ratings of all connected circuits.
- This circuit protection must be installed as close as possible to the battery.
- Each battery must be protected by a battery management system that provides under-voltage lockout protection.
- The battery management system should provide cell voltage monitoring, over-current protection, and over-voltage protection.
- Batteries should be connected to their battery management systems at all times, not only when installed on the rover.
- All wiring and connecting hardware between the battery and circuit protection must be fully secured and insulated such that no reasonable impact, vibration, loose object, or liquid could possibly create an unprotected short circuit.
- If multiple batteries are used, each must have its own fuse according to these requirements. You may not connect multiple batteries without a circuit protection element per battery.
- Multiple batteries may only be connected in series only if they feed a single circuit and each battery has a battery management system with under-voltage-lockout.
- Teams are responsible for the proper disposal of any compromised electrical components and/or batteries.
- Teams should store batteries in fireproof bags (ie Lipo storage bag).
- Each circuit must include separate circuit protection.
- The current rating of this protection must not exceed the lesser of:
- The current rating of the devices powered by the circuit, or 2 Amps for lower-current circuits;
- The safe current-carrying capacity of the smallest connectors or conductors in the circuit.
- Use this document as a guide for continuous current.
- In Drumheller the ambient temperature is 40 Celsius, where in CIRC Central and Niagara falls it will be 30C.
- The ambient temperature inside your rover is likely 20C higher than outdoors, depending on cooling strategy, rover material, paint colour, and other factors.
- The connections between your battery and any distribution board/panel are a circuit, and must be protected as such. Off the shelf battery management systems (BMSs) are allowable here, and are the only exception to the ban on protection systems that rely on software.
- Ventilation and heat dissipation concerns should be considered when installing power sources, high-current devices, and high-current wiring.
- Precautions against short circuits and electric shocks must be observed:
- Each battery must be securely mounted to a suitable structural element of the rover, and should be protected against collisions or roll overs during rover operation.
- All electrical wiring and connections must be insulated, taped over, or securely mounted within enclosed rover bodywork.
- All conductive objects within enclosed rover bodywork must be securely mounted to avoid contact with electrical connections.
- All electrical connections, wires, and traces should be insulated to prevent accidental short circuits.
- All electrical connections must be routed away from mechanical pinch points. The full range of motion available to the rover will be considered when evaluating pinch points.
- Hard stops should be used to limit mechanical movement and reduce pinch points
- Structural and mechanical elements of the rover must not be used as part of any electrical circuit.
- All power sources should be disconnected before servicing rover electrical systems.
- For the winter competition, all electronics should be within a waterproof container, or themselves be waterproof.
- For the summer competition, insulation and drainage should be considered.
- Sufficient documentation must be provided to prove the safety of your rover before you will be allowed to compete.
- You may submit partial or full documentation at any time for review and approval by the organizers. We recommend submitting potential designs early in the process if you have any concerns about whether they are compliant.
- You must submit a full copy of your documentation by January 15th, 2024 for review and approval. If your design is not compliant for this deadline, you will be allowed to revise and resubmit before a second deadline, to be determined on a case-by-case basis.
- Upon arrival at the competition, you will be required to submit a final hard-copy of your documentation, and your rover will be inspected for compliance to the requirements and consistency with the submitted documentation.
- A complete circuit diagram (block-level schematic) of the rover, including all power sources, circuit protection, and power-consuming devices, must be presented at CIRC sign-in.
- The documentation diagram should be updated to reflect ongoing changes during CIRC.
- The current hard copy of your documentation the diagram must accompany the rover to CIRC tasks.
- Related low-current devices on the same circuit may be grouped into black-box subsystems to reduce the complexity of the diagram.
- Each power source, circuit protection element, circuit, and device/device group in your documentation on the diagram must be identified annotated with a short name and current rating.
- Evidence of claimed current ratings must be provided in the documentation package.
- Acceptable evidence includes datasheets, industry standards, or test reports. Product pages or website screenshots are not acceptable.
- The documentation package must be accessible to judges at all times.
- A block-level schematic must be included in the documentation, and the layout of the schematic circuit diagram should reflect the physical layout of the rover wiring harness where possible.
- Related low-current devices (less than 2A total) on the same circuit may be grouped into black-box subsystems to reduce the complexity of the diagram.
- Each power source, circuit protection element, circuit, and device/device group in your documentation on the diagram must be identified annotated with a short name and current rating.
- A photograph of the emergency stop button mounted on the rover must be included.
- After any safety-related incident, your rover must pass a re-inspection before being allowed to continue competing. The re-inspection will include a discussion of the cause, and measures taken to prevent recurrence.
- Safety incidents include but are not limited to unprotected shorts, exposed or damaged wiring, battery damage, or any emission of smoke, fire, or sparks.
- A blown fuse or tripped circuit breaker is not a safety incident.
Commentary and changes:
- The rules around mounting of the emergency stop button are now more strict to ensure the buttons can be easily pressed by judges, and a photograph is required as part of the report.
- After several instances of dangerously discharged batteries we now require under-voltage lockout.
- We’ve updated our recommended wiring guide to one that provides corrections factors based on temperature, and set some expectations about choices of ambient temperatures.
- We’ve clarified our expectations about insulated connections on the rover.
- We will now be strictly enforcing rule 7.10 for safety related components, such as batteries and battery management systems, circuit protection, and emergency stop components.
- There is a new winter requirement related to waterproofing.